Line 16: | Line 16: | ||
It just works if Ex-Trigger is OFF.\\ | It just works if Ex-Trigger is OFF.\\ | ||
- | **set the steps:\\ | + | **set the steps:**\\ |
To change between 2 and 8 steps one can use the STEP potentiometer.\\ | To change between 2 and 8 steps one can use the STEP potentiometer.\\ | ||
If one select 1 step the Sync Sequencer goes into the **1 STEP MODE**. With the SPEED potentiometer one can now select each individual step. That makes it easy to program the sequencer.\\ | If one select 1 step the Sync Sequencer goes into the **1 STEP MODE**. With the SPEED potentiometer one can now select each individual step. That makes it easy to program the sequencer.\\ | ||
- | **change the speed:\\ | + | **change the speed:**\\ |
The speed can be set withe the SPEED potentiometer or with an external control voltage. For that the Ex-Speed switch has to be set on ON and with a jumper one can select between BUS 1 and BUS 2 as the CV source.\\ | The speed can be set withe the SPEED potentiometer or with an external control voltage. For that the Ex-Speed switch has to be set on ON and with a jumper one can select between BUS 1 and BUS 2 as the CV source.\\ | ||
If the Sync Sequencer is in the **STEP 1 MODE** instead of the speed the control voltage will change the individual step.\\ | If the Sync Sequencer is in the **STEP 1 MODE** instead of the speed the control voltage will change the individual step.\\ | ||
- | **external trigger** | + | **external trigger:**\\ |
If one wants to use an external trigger signal one has to set the Ex-Trigger switch on ON and then use the Gate for the trigger input or instead of the TRIGGER jumper one can attache an jumper wire to the marked pin.\\ | If one wants to use an external trigger signal one has to set the Ex-Trigger switch on ON and then use the Gate for the trigger input or instead of the TRIGGER jumper one can attache an jumper wire to the marked pin.\\ | ||
- | ---- | ||
+ | ---- | ||